← All guide topics

Performance specifications and critical interfaces

Define wind, air permeability, watertightness, thermal and acoustic requirements for the actual building. Use an appropriate façade assessment method rather than automatically applying the Uw of a window to an entire curtain wall.

Performance specifications and critical interfaces
EPIPHANY, Marousi · Façade works by TechnikAL.

What matters in practice

Coordinate anchors, movement joints, drainage, membranes, perimeter insulation and connections to adjacent materials. Fire performance and perimeter fire stopping require their own evidence and coordination with the fire strategy.

Define the performance brief

Set assessment methods, required performance, application zones and submission evidence. Catalogue values must be read with the scope of the relevant tests. Large or bespoke elements may require further calculations or testing.

Coordinate disciplines

Review connections to structure, insulation, roofs, services and internal finishes. Good individual products do not create a continuous air and water barrier if their interfaces remain unresolved.