← All guide topics

Glazing, acoustics and solar control

Select the complete glass build-up, not thickness alone. Thermal performance, light transmission and solar factor g need to match orientation and use. Acoustic selection should consider the noise source and the complete opening rather than the glass in isolation.

Glazing, acoustics and solar control
EPIPHANY, Marousi · Façade works by TechnikAL.

What matters in practice

Safety glazing, burglary resistance and protection against falling are distinct requirements. The appropriate build-up is selected for each position together with the frame and support conditions.

Daylight and summer comfort

Transparency alone is not a selection criterion. Radiation, shading and occupancy influence summer conditions. Selecting a very low solar factor without assessment may affect useful winter gains or the visual character of the elevation.

Assess acoustics and safety separately

Request the relevant acoustic index and glass build-up rather than judging by pane count. Define impact, post-breakage retention and fall-protection needs before ordering. Perimeter gaps and installation influence the completed opening.