Thermal performance: Uw, Uf and Ug

Uw describes the thermal transmittance of the whole window, Uf the frame and Ug the glazing. A lower value indicates reduced heat transfer, not automatically the best overall solution for every building. Dimensions, frame-to-glass ratio and the glazing spacer influence the result.

Thermal performance: Uw, Uf and Ug
Illustrative material: ALUMIL / TechnikAL archive.

What matters in practice

Request Uw for the actual window configurations. Assess solar gains, shading, ventilation and insulation continuity at installation as well. A low Ug must not be presented as the whole-window Uw.

Understanding the Uw calculation

For a simple window configuration: Uw = (Ag × Ug + Af × Uf + lg × ψg) / (Ag + Af). Ag and Af are glass and frame areas in m², lg is the glazing-edge length in m and ψg is linear thermal transmittance in W/(m·K). Uw is expressed in W/(m²·K). Other configurations require their appropriate assessment method.

Worked example, not a performance declaration